Fluke (FLU115)

Compact True-RMS Digital Multimeter
Compact True-RMS Digital Multimeter
List Price $302.31
Your Price Add to Cart to see price
Item Number FLU115
Mfg Fluke
Part No 115
free shipping
In stock: Yes

With its simple operation, compact design and ease of use, the Fluke® 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke® 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.

  • Large white LED backlight to work in poorly lit areas
  • Resistance and continuity
  • Frequency and capacitance
  • Maximum Voltage ac/dc 600V
  • 10A ac/dc current measurement (20 A overload for 30-seconds max)
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated
  • Safety conformance: All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
  • Includes:
    • Fluke® 115 Multimeter
    • Holster
    • 4 mm Silicone Test Lead set
    • User Manual
    • 9 Volt Battery (installed)

  • Specifications:
    • Maximum voltage between any terminal and earth ground: 600V
    • Surge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
    • Display: Digital - 6,000 counts, updates 4 per second
    • Bar graph: 33 segments, updates 32 per second
    • Operating Temperature: -10° C to + 50° C
    • Storage Temperature: -40° C to + 60° C
    • Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    • Battery Life: 400 hours typical, without backlight

  • Accuracy Specifications:
    • DC millivolts:
      Range - 600.0 mV
      Resolution: 0.1 mV
      Accuracy: +/- ([% of reading] + [counts]): 0.5% + 2
    • DC volts:
      Range/Resolution: 6.000 V / 0.001 V
      Range/Resolution: 60.00 V / 0.01 V
      Range/Resolution: 600.00 V / 0.1 V
      Accuracy: +/- ([% of reading] + [counts]): 0.5% + 2
    • AC millivolts1 true-rms:
      Range: 600.0 mV
      Resolution: 0.1 mV
      Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
    • AC volts1 true-rms:
      Range/Resolution: 6.000 V / 0.001 V
      Range/Resolution: 60.00 V / 0.01 V
      Range/Resolution: 600.00 V / 0.1 V
      Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz)
    • Continuity:
      Range: 600 ohms
      Resolution: 1 ohm
      Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer
    • Ohms:
      Range/Resolution: 600.0 Ω / 0.1 Ω
      Range/Resolution: 6.000 kΩ / 0.001 kΩ
      Range/Resolution: 60.00 kΩ / 0.01 kΩ
      Range/Resolution: 600.0 kΩ / 0.1 kΩ
      Range/Resolution: 6.000 MΩ / 0.001 MΩ
      Accuracy: 0.9 % + 1
      Range/Resolution: 40.00 MΩ / 0.01 MΩ
      Accuracy: 5 % + 2
    • Diode Test:
      Range/Resolution: 2.00 V / 0.001 V
      Accuracy: 0.9% + 2
    • Capacitance:
      Range/Resolution: 1000 nF / 1 nF
      Range/Resolution: 10.00 µF / 0.01 µF
      Range/Resolution: 100.0 µF / 0.1 µF
      Range/Resolution: 9999 µF / 1 µF
      Range/Resolution: 100 µF to 1000 µF
      Accuracy: 1.9% + 2
      Range/Resolution: > 1000 µF
      Accuracy: 5% + 20%
    • Lo-Z Capacitance:
      Range: 1 nF to 500 µF
      Accuracy: 10% + 2 typical
    • AC amps true-rms (45 Hz to 500Hz):
      Range/Resolution: 6.000 A / 0.001 A
      Range/Resolution: 10.00 A / 0.01 A
      Accuracy: 1.5% + 3, 20 A overload for 30-seconds max
    • DC amps:
      Range/Resolution: 6.000 A / 0.001 A
      Range/Resolution: 10.00 A / 0.01 A
      Accuracy: 1.0% + 3, 20 A overload for 30-seconds max
    • Hz (V or A input)2:
      Range/Resolution: 99.99 Hz / 0.01 Hz
      Range/Resolution: 999.9 Hz / 0.01 Hz
      Range/Resolution: 9.999 kHz / 0.001 kHz
      Range/Resolution: 50 kHz / 0.01 kHz
      Accuracy: 0.1% + 2

      Notes:
      1. All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
      2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
      3. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
      4. Temperature Range/Resolution: -40° F to 752° F / 0.2° F 
      5. Frequency is ac coupled, 5Hz to 30 kHz for ac voltage.

  • Mechanical & General Specifications
    • Size: 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
    • Weight: 550 g
    • Warranty: 3 years






DOWNLOAD: MANUAL

Related Products

SureGrip™ Aligator Clips
List Price $35.91
Your Price $18.22
free shipping
on sale
SureGrip™ Industrial Test Lead Set
List Price $120.51
Your Price $56.62
free shipping
on sale
80TK Thermocouple Module
List Price $217.71
Your Price $123.99
free shipping
on sale
SureGrip™ Electrical Test Lead Set
List Price $93.54
Your Price $68.86
free shipping
on sale
Premium Test Lead Set
List Price $45.62
Your Price $27.11
free shipping
on sale
TwistGuard™ Test Lead Set
List Price $43.11
Your Price $26.81
free shipping
on sale

Customer Support
online support link

call 1-800-794-6793
7:30am-4:00pm (cst)
Sign Up For Email
Get Great Deals
Delivered to
Your Inbox

Air Buffer Kit

Power Probe III

MICROFLEX DIAMOND GRIP GLOVES

TOOL STORAGE OPTIONS

BATTERY TOOLS

MECHANIX WEAR GLOVES